Applied-motion STAC6-C Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Hardware Applied-motion STAC6-C. Applied Motion STAC6-C User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - • STAC6-C • STAC6-C-220

• STAC6-S • STAC6-S-220• STAC6-Q • STAC6-Q-220• STAC6-QE • STAC6-QE-220• STAC6-Si • STAC6-Si-220• STAC6-C • STAC6-C-220 920-0029 Rev. C5/2/2012S

Página 2 - Contents

10STAC6 Hardware manual920-0029 Rev. C5/2/2012Getting StartedThis manual describes the use of STAC6 series of step motor drives. What you need to kno

Página 3

11STAC6 Hardware manual920-0029 Rev. C5/2/2012Connecting to the PC using RS-232• Locate your computer within 8 feet of the drive.• Your drive was ship

Página 4

12STAC6 Hardware manual920-0029 Rev. C5/2/2012Connecting to the PC using RS-485RS-485 allows you to connect more than one drive to a single host PC, P

Página 5

13STAC6 Hardware manual920-0029 Rev. C5/2/2012STAC6 drives include a “transmit delay” parameter that can be adjusted to compensate for a host that is

Página 6

14STAC6 Hardware manual920-0029 Rev. C5/2/2012USB-COMi-M Switch SettingsNote: Prolific-based USB serial adapters do not work with Vista 64 or Windows 7

Página 7

15STAC6 Hardware manual920-0029 Rev. C5/2/2012Connecting to the CANopen NetworkGNDCAN_LSHLDCAN_HThe CANopen connector is a 4-pin spring lock type conn

Página 8

16STAC6 Hardware manual920-0029 Rev. C5/2/2012Bit Rate SwitchThe CANopen network bitrate is set by the rotary switch on the front of the drive. The bi

Página 9

17STAC6 Hardware manual920-0029 Rev. C5/2/2012Connecting AC PowerUsing the connector supplied connect to the AC supply per the diagram below. Use 16 A

Página 10 - STAC6 Hardware manual

18STAC6 Hardware manual920-0029 Rev. C5/2/2012Connecting the MotorNever connect or disconnect the motor while the power is on.Note: it is highly reco

Página 11

19STAC6 Hardware manual920-0029 Rev. C5/2/2012A+A–B+ B–8 lead motor Series Connected8 Leads Parallel ConnectedA+A–B+ B–8leadmotorWhiteOrangeBrownGree

Página 12

2STAC6 Hardware manual920-0029 Rev. C5/2/2012ContentsSafety Instructions...

Página 13

20STAC6 Hardware manual920-0029 Rev. C5/2/2012Connecting Other MotorsWe can’t stress enough the wisdom in using one of the recommended motors. We’re n

Página 14

21STAC6 Hardware manual920-0029 Rev. C5/2/2012Eight lead motors can also be connected in two ways: series and parallel. As with six lead motors, ser

Página 15

22STAC6 Hardware manual920-0029 Rev. C5/2/2012Connecting an Encoder The motors recommended for use with STAC6 drives are available with rear-shaft mou

Página 16

23STAC6 Hardware manual920-0029 Rev. C5/2/2012Encoder Feedback OptionsThe following encoder feedback options are configured and enabled using the STAC

Página 17

24STAC6 Hardware manual920-0029 Rev. C5/2/2012Wiring Inputs and OutputsThe STAC6 drives come with a number of inputs and outputs for interfacing to ex

Página 18

25STAC6 Hardware manual920-0029 Rev. C5/2/2012Connecting Digital Inputs on the IN/OUT1 connectorHigh Speed Digital InputsAll STAC6 drives include two

Página 19

26STAC6 Hardware manual920-0029 Rev. C5/2/2012STAC 6IN/OUT 1DIR+DIR+DIR- DIR-STEP+STEP-STEP+STEP-IndexerwithDifferentialOutputsConnecting to Indexer w

Página 20

27STAC6 Hardware manual920-0029 Rev. C5/2/2012Using High Speed Inputs with 12-24 Volt SignalsMost PLCs don’t use 5 volt logic. You can connect signal

Página 21

28STAC6 Hardware manual920-0029 Rev. C5/2/2012Standard Digital InputsAs we mentioned above, the high speed STEP and DIR inputs are configured for five v

Página 22

29STAC6 Hardware manual920-0029 Rev. C5/2/2012What is COM? “Common” is an electronics term for an electrical connection to a common voltage. Sometimes

Página 23

3STAC6 Hardware manual920-0029 Rev. C5/2/2012(This page intentionally left blank)

Página 24

30STAC6 Hardware manual920-0029 Rev. C5/2/2012IN/OUT1NPN Proximity Sensor IN COM output + – - + NPN Proximity Sensor X3...X7X COMoutput + – 12-24 VDC

Página 25 - IN/OUT1 Connector

31STAC6 Hardware manual920-0029 Rev. C5/2/2012Connecting Limit switches to the STAC6 DriveThe X7/CW LIMIT and X6/CCW LIMIT inputs are used for connect

Página 26 - Wiring for Encoder Following

32STAC6 Hardware manual920-0029 Rev. C5/2/2012Wiring a Limit SensorSome systems use active limit sensors that produce a voltage output rather than a s

Página 27 - 5/2/2012

33STAC6 Hardware manual920-0029 Rev. C5/2/2012Connecting Digital Outputs on the IN/OUT1 connectorFront ViewX COMMONX7 / CW LimitX3 / EnableX5X4 / Ala

Página 28

34STAC6 Hardware manual920-0029 Rev. C5/2/2012Diagrams of different connections follow.Do not connect the outputs to more than 30VDC.The current thro

Página 29 - What is COM?

35STAC6 Hardware manual920-0029 Rev. C5/2/2012Connecting Analog Inputs on the IN/OUT1 connectorFront ViewX COMMONX7 / CW LimitX3 / EnableX5X4 / Alarm

Página 30

36STAC6 Hardware manual920-0029 Rev. C5/2/2012Basic Specifications:• The analog input can accept ±10 Volts.• The input has an impedance of 20K ohms.•

Página 31 - IN/OUT 1 Connector

37STAC6 Hardware manual920-0029 Rev. C5/2/2012Connecting Inputs and Outputs to IN/OUT2The IN/OUT2 connector is present as standard on the Si version o

Página 32

38STAC6 Hardware manual920-0029 Rev. C5/2/20122200 2200 2200 2200 2200 2200 inside IN/OUT2COM COM IN1 IN2 IN3 IN4 CWJOG CCWJOG COM Connecting an

Página 33 - Front View

39STAC6 Hardware manual920-0029 Rev. C5/2/2012Connecting another Si DriveIN/OUT2INCOMSi354, 7080i etcOUT+OUT–12-24VDCPowerSupply-+(When output closes,

Página 34

4STAC6 Hardware manual920-0029 Rev. C5/2/2012Safety InstructionsOnly qualified personnel are permitted to transport, assemble, commission, and maintain

Página 35

40STAC6 Hardware manual920-0029 Rev. C5/2/2012Differential Inputs The IN/OUT2 connector also includes two differential, optically isolated input circu

Página 36

41STAC6 Hardware manual920-0029 Rev. C5/2/2012Connecting an NPN Proximilty Sensor to a Differential InputSTAC6+DCPowerSupply–NPNProximitySensoroutput+

Página 37

42STAC6 Hardware manual920-0029 Rev. C5/2/2012Connecting Digital Outputs on the IN/OUT2 connector18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 2 3 1 19 20 21

Página 38 - (closed=logic low)

43STAC6 Hardware manual920-0029 Rev. C5/2/2012Do not connect the outputs to more than 30VDC. The current through each output terminal must not exceed

Página 39

44STAC6 Hardware manual920-0029 Rev. C5/2/2012Connecting Analog Inputs on the IN/OUT2 connector18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 2 3 1 19 20 21 2

Página 40 - Differential Inputs

45STAC6 Hardware manual920-0029 Rev. C5/2/2012Recommended MotorsApplied Motion offers 12 recommended motors for use with the STAC6 drives. All 12 of

Página 41

46STAC6 Hardware manual920-0029 Rev. C5/2/2012Motor DimensionsHT23 Motors1.11120” MIN.928"L"2X 2-56 UNC TAP THRU 180° APART ON A Ø19.05 B.C.

Página 42 - Digital Outputs

47STAC6 Hardware manual920-0029 Rev. C5/2/2012Motor DimensionsHT34 Motors Ø 2.875“L” .330 .0621.252X 2.744x Ø.218THRUØ .37501.12See shaft detail12

Página 43 - 1N4935 suppression diode

48STAC6 Hardware manual920-0029 Rev. C5/2/2012.875±.010.705Ø.6250+.000001.25±.02.18751.25±.02.875±.010.555.125Ø.500+.0000Shaft Detail 1 - motor with 0

Página 44

49STAC6 Hardware manual920-0029 Rev. C5/2/20120501001502002500 10 20 30 40 50(oz‐in)(rps)HT23‐552/553/554,STAC6(120)HT23‐552 HT23‐553 HT23‐554Connec

Página 45

5STAC6 Hardware manual920-0029 Rev. C5/2/2012• Never pull out or plug in the product while the system is live. There is a danger of electric arcing an

Página 46

50STAC6 Hardware manual920-0029 Rev. C5/2/2012Torque-Speed Curves 020040060080010001200140016000 10 20 30 40 50(oz‐in)(rps)HT34‐495/496/497,STAC6(12

Página 47

51STAC6 Hardware manual920-0029 Rev. C5/2/2012Torque-Speed Curves 0501001502002500 10 20 30 40 50(oz‐in)(rps)HT23‐548/549/550,STAC6(120)HT23‐548 HT2

Página 48

52STAC6 Hardware manual920-0029 Rev. C5/2/2012Mounting the DriveYou can mount your drive on the wide or the narrow side of the chassis using #6 screws

Página 49

53STAC6 Hardware manual920-0029 Rev. C5/2/2012Mechanical Outline.3007.345.120.150.50 TYP.76 TYP.1802.314.66.20.681.76.300.3006.3456.925

Página 50

54STAC6 Hardware manual920-0029 Rev. C5/2/2012Technical SpecificationsPOWER AMPLIFIER SECTIONAMPLIFIER TYPE MOSFET , Dual H-Bridge, 4 QuadrantCURRENT C

Página 51

55STAC6 Hardware manual920-0029 Rev. C5/2/2012 INPUTS AND OUTPUTSIN / OUT 1 connector - All Drives7 InputsX1, X2 Optically Isolated, Differentia

Página 52

56STAC6 Hardware manual920-0029 Rev. C5/2/2012Mating Connectors and AccessoriesMating Connector(Type)Included with Drive Additional/RecommendedMotor (

Página 53

57STAC6 Hardware manual920-0029 Rev. C5/2/2012Alarm CodesIn the event of an error, the green LED on the main board will ash one or two times, followe

Página 54 - Technical Specifications

6STAC6 Hardware manual920-0029 Rev. C5/2/2012Block Diagram - STAC6-Si, STAC6-Si-220MOSFET PWM Power Amplifier X1/STEPX2/DIRX3/ENABLEX4/ALMRSTX5X6/CCW

Página 55 - INPUTS AND OUTPUTS

7STAC6 Hardware manual920-0029 Rev. C5/2/2012Block Diagram - STAC6-S, STAC6-Q, STAC6-QE, STAC6-S-220, STAC6-Q-220, STAC6-QE-220MOSFET PWM Power Ampli

Página 56 - Accessories

8STAC6 Hardware manual920-0029 Rev. C5/2/2012Block Diagram - STAC6-C and STAC6-C-220MOSFET PWM Power Amplifier 120 VAC*X1/STEPX2/DIRX3/ENABLEX4/ALMRS

Página 57

9STAC6 Hardware manual920-0029 Rev. C5/2/2012Motion Control OptionsSTAC6-S Control OptionsBasic drive: Analog, digital and host command input.• Pulse

Comentários a estes Manuais