STR4/8 Hardware Manual
920-0030J
5/12/2015
If you plan to use a regulated power supply you may encounter a problem with regeneration.
If you rapidly decelerate a load from a high speed, much of the kinetic energy of that load is
transferred back to the power supply. is can trip the overvoltage protection of a switching
power supply, causing it to shut down. We oer the RC-050 “regeneration clamp” to solve this
problem. If in doubt, buy an RC-050 for your rst installation. If the “regen” LED on the RC-050
neverashes,youdon’tneedtheclamp.
RC-050 Regen Clamp
Power Supply and Ground Connections
Locate fuse in-line with “+” connection
regen LED