CONTROLLER: -S, -Q, -IP Models
IN1 Optically isolated, 5-24 V, 8-12 mA. Minimum pulse width = 250 ns.
Maximum pulse frequency = 3 MHz. Adjustable bandwidth digital
noise rejection lter
Function: CW limit, general purpose input.
IN2 Optically isolated, 5-24 V, 8-12 mA. Minimum pulse width = 250 ns.
Maximum pulse frequency = 3 MHz. Adjustable bandwidth digital
noise rejection lter
Function: CCW limit, general purpose input.
IN3 Optically isolated, 5-24 V, 8-12 mA.
Function: home sensor, general purpose input.
OUT Optically isolated, 30V, 40mA MAX. open emitter/collector.
Function: fault, motion, alarm, tach or general purpose