Analog Input
e STM23S/Q/IP drives feature an analog input (not available on STM23C drives). e input can accept a signal
range of 0 to 5 VDC. e drive can be congured to operate at a speed or position that is proportional to the
analog signal. Use the
ST Congurator
soware to set the signal range, oset, dead-band and lter frequency. e
STM23 drives provide a 5 volt DC, 50 mA output labeled +5V that can be used to power external devices such as
potentiometers. It is not the most accurate supply for reference; for more precise readings use an external supply
that can provide the desired accuracy.
Connecting a Potentiometer to the Analog Input
inside drive
AIN
GND
Signal
Conditioning
+5V
50ma Limit
I/O Connector
1-10k Ohm
potentiometer
cw
ccw
GND