1/30/2014
e actual temperature of the motor depends on how much heat is conducted, convected or
radiated out of it. Our measurements were made in a 40°C (104°F) environment with the motor
mounted to an aluminum plate sized to provide a surface area consistent with the motor power
dissipation. Your results may vary.
Motor Connection
Current
Seing (A)
Max Duty Cycle at 40°C Ambient
12VDC 24VDC 48VDC
HT08-020 4 leads 0.42 100% 100% NR
HT08-021 4 leads 0.42 100% 100% NR
HT11-012 4 leads 1.20 100% 100% NR
HT11-013 4 leads 1.20 100% 100% NR
5014-042 4 leads 1.00 100% see chart NR
HT17-268 parallel 1.61 100% 100% see chart
HT17-271 parallel 2.04 100% 100% see chart
HT17-275 parallel 2.04 100% 100% see chart
HT23-595 series 2.20 100% 100% 100%
HT23-598 series 2.20 100% 100% 100%
HT23-601 series 2.20 100% 100% 100%
NR: power supply voltage is not recommended for this motor