Applied-motion ST10-Plus Manual do Utilizador Página 11

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 36
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 10
11
ST5/10-S Hardware manual
920-0027 Rev. D
2/7/14
Connecting to Indexer with Differential Outputs
(Many High Speed Indexers have Differential Outputs)
Connecting to indexer with Sourcing Outputs
Connecting to Indexer with Sinking Outputs
High Speed Digital Inputs (STEP, DIR)
The -S drives include two high speed inputs labeled STEP and DIR. They accept 5 volt single-ended or differential
signals, up to 2 MHz.
STEP and DIR Inputs are congured using the ST Congurator software.
The inputs can connect to an indexer, a master encoder or CNC handwheel for following applications, or they can
be used for connecting sensors, switches and other electronic devices. They can be used as the run/stop and
direction inputs for velocity (oscillator) mode.
Connection diagrams follow.
ST5/10-S
COM
DIR-
DIR DIR+
STEP-
STEP STEP+
Indexer
with
Sourcing
Outputs
ST5/10-S
+5V OUT
DIR+
DIR DIR-
STEP+
STEP STEP-
Indexer
with
Sinking
Outputs
STM23
DIR+
DIR+
DIR- DIR-
STEP+
STEP-
STEP+
STEP-
Indexer
with
Differential
Outputs
Vista de página 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 ... 35 36

Comentários a estes Manuais

Sem comentários