920-0042C
ST5/10-C Quick Setup Guide
Step 2 - CANOpen Setup
Connect to CAN network.
Applied Motion Products ST5/10-C drives use a four-pin
spring connector, that conforms to the DR303 specication.
The connector should be wired in a daisy-chain conguration
with a 120 Ohm resistor used to terminate each end.
Switch Setting Resultant Bit Rate
0 1 Mbps
1 800kbps
2 500 kbps
3 250 kbps
4 125 kbps
5 50 kbps
6 20 kbps
7 12.5 kbps
8
n/a
9 n/a
Bit Rate Table
Connect the drive to your PC using the RS-232 programming cable.
Download and install ST Congurator™ software, available at www.applied-motion.com.
Launch the software by clicking Start/Programs/Applied Motion Products/ST Congurator
Step 3 - Configuration
Apply power to the drive.
Use the ST Congurator™ to set up the motor current, load iner-
tia, limit switches and encoder functionality (if applicable).
The ST Congurator™ includes a self test option (under the Drive menu)
to verify that the ST5/10-C and motor are correctly wired and congured.
When conguration is complete, exit ST Congurator™. The
drive will automatically switch to CANOpen Mode.
If you have any questions or comments, please call Applied Motion Products
Customer Support (800)525-1609 or visit us online at www.applied-motion.com.
404 Westridge Dr.
Watsonville, CA 95076
Tel: 800-525-1609
Fax: 831-761 -6544
www.applied-motion.com
If you have any questions or comments,
please call Applied Motion Products
Customer Support: (800) 525-1609,
or visit us online at www.applied-motion.com.
Set BitRate, Node ID
CANOpen Bitrate - AMP CANOpen drives have three settings, one for Bit Rate and two for Node
ID. The Bit Rate is congured using an eight-position switch. See Bit Rate table for the Bit Rate
settings. The Node ID is congured using a sixteen position switch to set up the lower four bits
of the Node ID. The upper three bits of the Node ID are set using an additional 8 position switch
located under the cover on the CANOpen motherboard. Valid ranges for the Node ID are 0x01
through 0x7F. Node ID 0x00 is reserved in accordance with the DS301 specication.
Note: The Node ID and Bit Rate are captured only after a power cycle, or after a network reset
command has been sent. Changing the switches while the drive is powered on will NOT change
the Node ID or Bit Rate until one of these conditions has been met.